28 DAY TEST APPARATUS FOR MCB

28 DAY TEST APPARATUS FOR MCB

As Per IEC: 60898

SENSORS 28-Day Test and Temperature Rise Apparatus for MCB (As Per IEC: 60898 -1:2002) is developed to perform the following : 28 DAY TEST APPARATUS FOR MCB

28 days Test to perform 28 days Test. The MCB is exposed to 28 cycles, Each cycle comprising 21 hours with rated current more than 30 Volts. And 3 hours without current. PLC is used to maintain the cycle. Complete PLC controlled system to test MCB as per the standards requirement.

Temperature Rise Test Temperature Rise Test also can be carried out of Constant Current Source. Digital Temperature Scanner with 12 channels.

Watt Loss Test The watt loss measurement at rated current and at open voltage of more than 30 Volt AC. carried out with this panel. Digital Milli Volt Meter is provided for Voltage measurement.

The apparatus test is designed so ergonomically that the once program  is in run mode it will annunciate the PASS FAIL results as per standards requirement.

The circuit-breaker is subjected to 28 cycles, each cycle comprising 21 h with a current equal to the rated current at an open circuit voltage of at least 30 V, and 3 h without current under the test conditions of  the circuit-breaker is in the closed position, the current being established and interrupted by an auxiliary switch. During this test the circuit-breaker shall not trip .
During the last period of current flow the temperature-rise of the terminals shall be measured. provision to test temperature-rise of different places of the MCB.

 

28 DAY TEST APPARATUS