{"id":655,"date":"2018-07-18T18:22:13","date_gmt":"2018-07-18T12:52:13","guid":{"rendered":"http:\/\/sensorsindia.in\/?page_id=655"},"modified":"2018-07-20T17:04:36","modified_gmt":"2018-07-20T11:34:36","slug":"endurance-test-for-hot-air-fan","status":"publish","type":"page","link":"https:\/\/sensorsindia.in\/index.php\/electricals\/endurance-test-for-hot-air-fan\/","title":{"rendered":"ENDURANCE TEST FOR HOT AIR FAN"},"content":{"rendered":"<h1 style=\"text-align: center;\">ENDURANCE TEST FOR HOT AIR FAN<\/h1>\n<h2 style=\"text-align: center;\">As per\u00a0 IS: 4283:1981<\/h2>\n<p><strong>ENDURANCE TEST FOR HOT AIR FAN<\/strong> apparatus is designed as per the standard IS: 4283:1981, clause no. 8.14.13.1. Thermostat is loaded with its rated current at its rated voltage and is made to operate 10,000 times (making &amp; breaking) at a rate in accordance with the normal switching frequency inherent to the fan.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-656\" title=\"Endurance Test Apparatus for Hot Air Fan\" src=\"http:\/\/sensorsindia.in\/wp-content\/uploads\/2018\/07\/Endurance-Test-Apparatus-for-Hot-Air-Fan.png\" alt=\"Endurance Test Apparatus for Hot Air Fan\" width=\"358\" height=\"389\" srcset=\"https:\/\/sensorsindia.in\/wp-content\/uploads\/2018\/07\/Endurance-Test-Apparatus-for-Hot-Air-Fan.png 450w, https:\/\/sensorsindia.in\/wp-content\/uploads\/2018\/07\/Endurance-Test-Apparatus-for-Hot-Air-Fan-276x300.png 276w\" sizes=\"(max-width: 358px) 100vw, 358px\" \/><\/p>\n ","protected":false},"excerpt":{"rendered":"<p>ENDURANCE TEST FOR HOT AIR FAN As per\u00a0 IS: 4283:1981 ENDURANCE TEST FOR HOT AIR FAN apparatus is designed as per the standard IS: 4283:1981, clause no. 8.14.13.1. Thermostat is loaded with its rated current at its rated voltage and is made to operate 10,000 times (making &amp; breaking) at a rate in accordance with<a href=\"https:\/\/sensorsindia.in\/index.php\/electricals\/endurance-test-for-hot-air-fan\/\">[&#8230;]<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":86,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-fullwidth.php","meta":{"footnotes":""},"class_list":["post-655","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ENDURANCE TEST FOR HOT AIR FAN - SENSORS INDIA<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sensorsindia.in\/index.php\/electricals\/endurance-test-for-hot-air-fan\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ENDURANCE TEST FOR HOT AIR FAN - SENSORS INDIA\" \/>\n<meta property=\"og:description\" content=\"ENDURANCE TEST FOR HOT AIR FAN As per\u00a0 IS: 4283:1981 ENDURANCE TEST FOR HOT AIR FAN apparatus is designed as per the standard IS: 4283:1981, clause no. 8.14.13.1. Thermostat is loaded with its rated current at its rated voltage and is made to operate 10,000 times (making &amp; breaking) at a rate in accordance with[...]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sensorsindia.in\/index.php\/electricals\/endurance-test-for-hot-air-fan\/\" \/>\n<meta property=\"og:site_name\" content=\"SENSORS INDIA\" \/>\n<meta property=\"article:modified_time\" content=\"2018-07-20T11:34:36+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/sensorsindia.in\/wp-content\/uploads\/2018\/07\/Endurance-Test-Apparatus-for-Hot-Air-Fan.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/sensorsindia.in\\\/index.php\\\/electricals\\\/endurance-test-for-hot-air-fan\\\/\",\"url\":\"https:\\\/\\\/sensorsindia.in\\\/index.php\\\/electricals\\\/endurance-test-for-hot-air-fan\\\/\",\"name\":\"ENDURANCE TEST FOR HOT AIR FAN - SENSORS INDIA\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/sensorsindia.in\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/sensorsindia.in\\\/index.php\\\/electricals\\\/endurance-test-for-hot-air-fan\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/sensorsindia.in\\\/index.php\\\/electricals\\\/endurance-test-for-hot-air-fan\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/sensorsindia.in\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/Endurance-Test-Apparatus-for-Hot-Air-Fan.png\",\"datePublished\":\"2018-07-18T12:52:13+00:00\",\"dateModified\":\"2018-07-20T11:34:36+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/sensorsindia.in\\\/index.php\\\/electricals\\\/endurance-test-for-hot-air-fan\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/sensorsindia.in\\\/index.php\\\/electricals\\\/endurance-test-for-hot-air-fan\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/sensorsindia.in\\\/index.php\\\/electricals\\\/endurance-test-for-hot-air-fan\\\/#primaryimage\",\"url\":\"https:\\\/\\\/sensorsindia.in\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/Endurance-Test-Apparatus-for-Hot-Air-Fan.png\",\"contentUrl\":\"https:\\\/\\\/sensorsindia.in\\\/wp-content\\\/uploads\\\/2018\\\/07\\\/Endurance-Test-Apparatus-for-Hot-Air-Fan.png\",\"width\":450,\"height\":489,\"caption\":\"Endurance Tester Hot Air Fan\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/sensorsindia.in\\\/index.php\\\/electricals\\\/endurance-test-for-hot-air-fan\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/sensorsindia.in\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical\",\"item\":\"https:\\\/\\\/sensorsindia.in\\\/index.php\\\/electricals\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ENDURANCE TEST FOR HOT AIR FAN\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/sensorsindia.in\\\/#website\",\"url\":\"https:\\\/\\\/sensorsindia.in\\\/\",\"name\":\"SENSORS INDIA\",\"description\":\"&quot;INNOVATIVE TEST SYSTEM DESIGNERS&quot;\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/sensorsindia.in\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ENDURANCE TEST FOR HOT AIR FAN - SENSORS INDIA","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sensorsindia.in\/index.php\/electricals\/endurance-test-for-hot-air-fan\/","og_locale":"en_US","og_type":"article","og_title":"ENDURANCE TEST FOR HOT AIR FAN - SENSORS INDIA","og_description":"ENDURANCE TEST FOR HOT AIR FAN As per\u00a0 IS: 4283:1981 ENDURANCE TEST FOR HOT AIR FAN apparatus is designed as per the standard IS: 4283:1981, clause no. 8.14.13.1. Thermostat is loaded with its rated current at its rated voltage and is made to operate 10,000 times (making &amp; breaking) at a rate in accordance with[...]","og_url":"https:\/\/sensorsindia.in\/index.php\/electricals\/endurance-test-for-hot-air-fan\/","og_site_name":"SENSORS INDIA","article_modified_time":"2018-07-20T11:34:36+00:00","og_image":[{"url":"http:\/\/sensorsindia.in\/wp-content\/uploads\/2018\/07\/Endurance-Test-Apparatus-for-Hot-Air-Fan.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/sensorsindia.in\/index.php\/electricals\/endurance-test-for-hot-air-fan\/","url":"https:\/\/sensorsindia.in\/index.php\/electricals\/endurance-test-for-hot-air-fan\/","name":"ENDURANCE TEST FOR HOT AIR FAN - SENSORS INDIA","isPartOf":{"@id":"https:\/\/sensorsindia.in\/#website"},"primaryImageOfPage":{"@id":"https:\/\/sensorsindia.in\/index.php\/electricals\/endurance-test-for-hot-air-fan\/#primaryimage"},"image":{"@id":"https:\/\/sensorsindia.in\/index.php\/electricals\/endurance-test-for-hot-air-fan\/#primaryimage"},"thumbnailUrl":"http:\/\/sensorsindia.in\/wp-content\/uploads\/2018\/07\/Endurance-Test-Apparatus-for-Hot-Air-Fan.png","datePublished":"2018-07-18T12:52:13+00:00","dateModified":"2018-07-20T11:34:36+00:00","breadcrumb":{"@id":"https:\/\/sensorsindia.in\/index.php\/electricals\/endurance-test-for-hot-air-fan\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sensorsindia.in\/index.php\/electricals\/endurance-test-for-hot-air-fan\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/sensorsindia.in\/index.php\/electricals\/endurance-test-for-hot-air-fan\/#primaryimage","url":"https:\/\/sensorsindia.in\/wp-content\/uploads\/2018\/07\/Endurance-Test-Apparatus-for-Hot-Air-Fan.png","contentUrl":"https:\/\/sensorsindia.in\/wp-content\/uploads\/2018\/07\/Endurance-Test-Apparatus-for-Hot-Air-Fan.png","width":450,"height":489,"caption":"Endurance Tester Hot Air Fan"},{"@type":"BreadcrumbList","@id":"https:\/\/sensorsindia.in\/index.php\/electricals\/endurance-test-for-hot-air-fan\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/sensorsindia.in\/"},{"@type":"ListItem","position":2,"name":"Electrical","item":"https:\/\/sensorsindia.in\/index.php\/electricals\/"},{"@type":"ListItem","position":3,"name":"ENDURANCE TEST FOR HOT AIR FAN"}]},{"@type":"WebSite","@id":"https:\/\/sensorsindia.in\/#website","url":"https:\/\/sensorsindia.in\/","name":"SENSORS INDIA","description":"&quot;INNOVATIVE TEST SYSTEM DESIGNERS&quot;","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sensorsindia.in\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/sensorsindia.in\/index.php\/wp-json\/wp\/v2\/pages\/655","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sensorsindia.in\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/sensorsindia.in\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/sensorsindia.in\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sensorsindia.in\/index.php\/wp-json\/wp\/v2\/comments?post=655"}],"version-history":[{"count":3,"href":"https:\/\/sensorsindia.in\/index.php\/wp-json\/wp\/v2\/pages\/655\/revisions"}],"predecessor-version":[{"id":716,"href":"https:\/\/sensorsindia.in\/index.php\/wp-json\/wp\/v2\/pages\/655\/revisions\/716"}],"up":[{"embeddable":true,"href":"https:\/\/sensorsindia.in\/index.php\/wp-json\/wp\/v2\/pages\/86"}],"wp:attachment":[{"href":"https:\/\/sensorsindia.in\/index.php\/wp-json\/wp\/v2\/media?parent=655"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}